Custom designed modifications are our standard
As a customer-specific global supplier, we know: "customer-specific means satisfying innovative demands". SYKO is a top address for innovative system solutions |
General informations: | |
30 and more custom designed modification per year | |
extreme requirements | |
shock, vibration | |
temperature | |
supply fluctuations | |
disturbances, lightning strikes, load throw-off in inductive networks | |
network interruptions | |
voltage interruptions by starting activities | |
innovative, patented topologies | |
step-up- step-down converter with or without isolation | |
Regenerator topology (US pat. no. 5.991.166, D. pat. no. 195 15 210) | |
Input values: | |
24 / 36 / 48 / 60 / 96 / 110V batteries | |
13,5 - 154 V in one range + transienten up to 300 V | |
12 / 24 / 42V batteries | |
4 - 38 / 6 - 38 / 9 - 85V + transients up to 110V | |
18V DC - 264V AC (universal input) | |
400V - 1200V DC | |
600V - 1600V DC | |
680V - 5000V DC/AC + transients up to 16 kV / 2 ms | |
Output values: | |
up to >15 output voltages | |
no load proof, short circuit proof, over load protected, no intercircuit interferences | |
output voltage 2 - 640V with input voltage ranges up to 1:20 | |
with or without galvanic isolation | |
System extensions: | |
active transient filter (SYKO patent-no. 0402367 + 3804074) for inrush current limiting and overvoltage protection (transienten kill) |
|
active hold-up time
10ms - 1s by DC- and AC-input, constant from min. to max. input voltage |
|
extension of active hold-up time with capacitors up to seconds or with batteries/accus up to hours |
|
additional outputs free of transients and EMC-"clean", with or without galvanic isolation from the input potential |
|
disengageable outputs Inhibit-function |
|
combination of low- and high voltage outputs with very wide input ranges |
|
readjustment of outputs with approx. 100mV dropout voltage per 5A output current |
|
controlled outputs with total output power of the supply for heating or cooling with polarity change (peltier-elements) |
|
setpoint values with reference voltage or reference current |
|
actual values as reference voltage or reference current |
|
inverse-polarity protection passiv (diode) or activ (reduce of power dissipation) |
|
increase of power and input voltage with cascaded Regenerator-power stages US pat. no. 6.094.366, D. pat. no. 195 05 417 |
|
one-step PFC on AC-input voltages up to 2100V / 16,3 up to 60Hz as sinus or square wave signal |
|
minimal modification times 6 - 10 weeks from incoming order till delivery of the first preseries |
When the market talks about developing or modifikation costs of 50000 euro, SYKO shows according to the customer satisfaction very flexible costs with an average of 10000 euro. This is shown by a variety of new designs, which will be finished continuously and parallel in the next time. |